L.B. White Foreman 500 Propane/NG Indirect-Fired Heater
$8,129.00
The L.B. White Foreman 500 Propane/NG (Link Capable) indirect-fired heater is a portable indirect-fired heater that can operate using propane or natural gas. The machine produces 500,000 BTUs of fume-free heat with 3,457 cubic feet a minute air volume. For a custom quote, please call 833-401-3569 ext. 2.
PLEASE NOTE:
- Call to inquire on lead time.
- Not suitable for elevations above 6,000 feet.
- Ships via truck freight to commercial dock.
- Additional shipping charges will apply for liftgate, rural, limited access and residential delivery.
- Not returnable – Please double check to confirm this product is correct for your application.
Filters Sort results Reset Apply Image Details The L.B. White Foreman 500 Propane/NG (Link Capable) indirect-fired heater… $8,129.00 Max: Min: 1 Step: 1 Add to cart Dual Fuel regulator for use with select L.B. White heaters… $1,401.00 Max: Min: 1 Step: 1 Add to cart 12" diameter 25' long high temperature, flexible ducting used in… $350.00 Max: Min: 1 Step: 1 Add to cart Mechanical thermostat for use with L.B. White heaters, Nema 4x… $115.00 Max: Min: 1 Step: 1 Add to cart 6" chimney exhaust, compatible with the following indirect fired heaters:Journeyman… $101.60 Max: Min: 1 Step: 1 Add to cart 6" rain cap, compatible with the following indirect fired heaters:Journeyman… $54.74 Max: Min: 1 Step: 1 Add to cart
Image | Details |
|---|---|
| The L.B. White Foreman 500 Propane/NG (Link Capable) indirect-fired heater… $8,129.00 Max: Min: 1 Step: 1 Add to cart | |
| Dual Fuel regulator for use with select L.B. White heaters… $1,401.00 Max: Min: 1 Step: 1 Add to cart | |
| 12" diameter 25' long high temperature, flexible ducting used in… $350.00 Max: Min: 1 Step: 1 Add to cart | |
| Mechanical thermostat for use with L.B. White heaters, Nema 4x… $115.00 Max: Min: 1 Step: 1 Add to cart | |
| 6" chimney exhaust, compatible with the following indirect fired heaters:Journeyman… $101.60 Max: Min: 1 Step: 1 Add to cart | |
| 6" rain cap, compatible with the following indirect fired heaters:Journeyman… $54.74 Max: Min: 1 Step: 1 Add to cart |
Description
The L.B. White Foreman 500 Propane/NG indirect-fired heater is a portable indirect-fired heater that can operate using propane or natural gas. The system comes Link Capable, which is LB White’s proprietary real-time heater monitoring system(requires subscription to be used). Key features of the L.B. White Foreman 500DF Heater include:
- 500,000 BTUs of heat
- 3,457 CFM
- Ductable to 50’ on dual 12” ports
- Thermostatically Controlled with optional thermostat
- CSA safety certified
- Sturdy frame with integral wheels for transport
- Sealed motor for outdoor operation in all types of weather
- Portable
- Optional forklift pockets
- Two-Year Warranty
*Note- Heater only,does not include accessories. This heater requires (2)12″ diameter sections of ducting. There is also an optional thermostat that can be supplied with the machine, external gas accessories like a 1st stage regulator and gas hose. Additonally, there is also an option duct adapter that converts from dual 12″ diameter to a single 16″ adapter. If you would like to use the machine with natural gas supply, confirm that the meter rating and supply pressure matches the requirements of the machine. Please see our video on verifying your gas meter has a proper supply rating.
The L.B. White Foreman 500 Propane/NG Indirect-Fired Heater can be used in applications such as:
Climate Control- Temporary heating of warehouse spaces where higher amounts of BTUs are required, or larger events to heat tents and other non-permanent structures. The heater can raise the temperature of the space by 40 degrees F in a 200,000 cubic feet space(i.e. 14,300 sq. ft. with 14′ ceilings) in moderately insulated structures. For a more precise heat load requirement for your particular application, consult our heating guide or contact our office at 833-401-3569.
Disaster Restoration- Heat drying to increase and promote rapid evaporation of wet structures to aid in drying the structure to return to pre-loss condition. This system can be used as an open drying system, or a partial recirculation, with the flue pipe being piped to the outside of the structure.
-Many other process heating applications such bed bug treatments, lumber drying, etc.
To see the product’s portability, click here.
| L.B. White | Foreman 500DF |
| BTU/H rating | 500,000 |
| Heated air output (CFM) | 2,350 |
| Blower Fan (CFM) | 3,457 |
| Fuel Type | LP, NG |
| Fuel consumption | 23 LP lbs/hr, 500 NG cu.ft/hr |
| Amps (start/continuous) | 60/15 |
| Electric supply (volts/hz/phase) | 120/60/1 |
| Motor horsepower | 1 |
| Unit Dimensions | 84.4” l x 32”w x 52.5”h, 617 lbs |
| Outlet Static Pressure (IN W.C.) | 2.5 |
| Outlet duct diameter (in) | 12”x2 |
| Outlet duct max length (ft) | 50’ on each port |
| Recirculation Duct Diameter (in) | 20” |
| Third Party Certified | ANSIZ83.7/CSA 2.14-2017 |



Reviews