Sure Flame IX1500
$51,899.00
1,500,000 BTU Dual-Fuel Indirect Fired Construction Heater, intended to be used primarily for the temporary heating of buildings under construction, alteration or repair.
PLEASE NOTE:
- Ships via truck freight to commercial dock.
- Additional shipping charges will apply for liftgate, rural, limited access and residential delivery.
- Not returnable – Please double check to confirm this product is correct for your application.
Description
The Sure Flame IX1500 Model is an 1.5 million BTU, indirect-fired gas heater intended to be used primarily for the temporary heating of buildings under construction, alteration or repair.
Product Features:
- CSA approved
- Quick Change fuel supply – Dual fuel selector valve
- Compact Design – uses less space on the job site and during the off season
- 3 safety shut down controls (High limit switch, Air switch, and Flame Rod)
- Forklift Accessible side and ends
- Multiple power configurations options
- 2- stage remote thermostat control
- Stainless steel patented heat exchanger
- Stainless steel Burner
- 90% efficiency
The Sure Flame IX1500 can be ducted on both the inlet and outlet. The inlet duct can be up to 50′ of smooth 24”x24″ metal duct The outlet duct shall be of a material able to withstand temperatures of up to 450°F. Total outlet duct length may be up to 300′ of straight, smooth, insulated metal duct 24”x24”. For each elbow, the allowable length is reduced by 50’. Since it is an indirect-fired heater, the machine discharges only clean, fume free heat.
Venting
The flue material is to be constructed of a Type B (Type BH in Canada), Category III venting material. The vent connector should be designed for a positive pressure and be constructed from material having corrosion resistance and durability to heat at last equivalent to that of No. 24 GSG galvanized steel. The venting system must be in accordance with the Installation Codes for Gas Burning Appliances and Equipment, as well as other local regulations that may apply. Since the products of combustion are released, it is imperative that the flue stack is extended outside of the enclosed area when the heater is positioned indoors. The flow of supply air and exhaust gasses must not be obstructed in any manner.
Product Specifications
<table class=”table”>
<tbody>
<tr>
<td><strong>Input</strong></td>
<td>1,500,000 BTU/hr</td>
</tr>
<tr>
<td><strong>Fuel</strong></td>
<td>
<ul>
<li>Vapor Propane</li>
<li>Natural Gas</li>
</ul>
</td>
</tr>
<tr>
<td><strong>Fuel Consumption</strong></td>
<td>
<ul>
<li>16.4 GPH LP</li>
<li>1,500 CFH NG</li>
</ul>
</td>
</tr>
<tr>
<td><strong>Gas Connection</strong></td>
<td>1 1/2″ NPT</td>
</tr>
<tr>
<td><strong>Gas Pressure</strong></td>
<td>1/2 – 5 psi</td>
</tr>
<tr>
<td><strong>Fan</strong></td>
<td>22,000 CFM</td>
</tr>
<tr>
<td><strong>Temperature Rise</strong></td>
<td>171 degrees</td>
</tr>
<tr>
<td><strong>Electrical</strong></td>
<td>240/480V, 30 Amp, 3 phase</td>
</tr>
<tr>
<td><strong>Thermostat</strong></td>
<td>On/Off</td>
</tr>
<tr>
<td><strong>Weight</strong></td>
<td>1,875 lbs.</td>
</tr>
<tr>
<td><strong>Ductable</strong></td>
<td>up to 400′</td>
</tr>
<tr>
<td><strong>Dimensions</strong></td>
<td>114″ L
32.5″ W
77.5″ H</td>
</tr>
</tbody>
</table>